Control _Ino-Energy  Ino-Energy

Ino-Energy

Control

2021-12-02 13:42:05 263

HLDP07-Series Explosion-proof electrical apparatus (Control circuit)


87a3532b5309f496e7c8ae7a81191292.jpg

Ex II2 G Ex db IIB T6 Gb 

Ex II2 G Ex db [ia/ib] llB T6 Gb

Ex II2 G Ex db IIB+H2 T6 Gb

Ex II2 G Ex db [ia/ib] llB+H2 T6 Gb 

Ex II2 D Ex tb IIIC T80℃ Db


Zone I and Zone 2

Zone 21 and Zone 22


IP66 , IP67


-20℃~+60℃

-40℃~+ 60℃



HLBX02-Series Explosion-proof Control stations


540ec17300ef5cc15e46d0afce977e8f.jpg

Ex II2 G Ex db eb IIC T6 Gb

Ex II2 D Ex tb IIIC T80℃ Db


Zone I and Zone 2

Zone 21 and Zone 22


IP66


Max.-40℃ ~+ 70℃



PXK-Series positive pressure explosion-proof power distribution cabinets


1f37adf8883d0d47a30dd6b57e365449.png

Ex d e ib mb px IIC T4 Gb 

Ex d e ib mb pz IIC T6 Ge 

Ex ibD mD pD tD A21 IP66 T80℃


Zone 1 and Zone 2

Zone 21 and Zone 22


lp66



HLDP06-Series Explosion-proof electrical apparatus (Control motor system)


62683145f021451d4a5a6be4ea7969c8.jpg

Ex II2 G Ex db IIB T6/T5 Gb

Ex II2 G Ex db IIB+H2 T6/T5 Gb

Ex II2 D Ex tb IlIC T80/T95℃ Db


Zone 1 and Zone 2

Zone 21 and Zone 22


IP66, IP67


T6/T5:-20℃~+60℃

          -40℃~+60℃



HLDP05-Series Explosion-proof electrical apparatus (Control loop opening and breaking)


79679b59813389647c75813f0922594e.jpg

Ex II2 G Ex db IIB T6/T5 Gb

Ex II2 G Ex db IIB+H2 T6/T5 Gb

Ex II2 D Ex tb IlIC T80/T95℃ Db


Zone 1 and Zone 2

Zone 21 and Zone 22


IP66 , IP67


T6/T5:-20℃~ + 60℃, -40℃~+ 60℃



HJLBD05-Seriess explosion-proof LED lightings 


666efd576a9af61e98c389f909cf3525.png

Ex d IIC T6 Gb

Ex tD A21 IP66 T80℃


Zone I and Zone 2

Zone 21 and Zone 22


IP66


-60℃~+55℃



BCZ8060-Series explosion-proof anti-corrosion plug and sockets


8ecac1598214a1bc525ec7916cfb7160.png

Ex de IIC T6 Gb (16, 32A)

Ex tD A21 IP65 T80℃

Ex de IIC T5 Gb (63A, 125A)

Ex tD A21 IP66 T80℃


Zone 1 and Zone 2

Zone 21 and Zone 22


IP65



HLBM13/14-Series explosion-proof cable glands (Armored)


Ex d II C Gb (G thread not applicable) 

Ex e II C Gb 

Ex tD A20 IP66 / 67


Zone I and Zone 2 

Zone 20, Zone 21 and Zone 22

 

- 40 ℃ ≤ Tservice ≤+100 ℃

- 60 ℃ ≤ Tservice ≤+100 ℃


IP66. IP67

a239a44d7aa1e7f6879b518b1f69e57c.png



HLBM15/16-Series explosion-proof cable glands(Unarmored)


Ex d II C Gb (G thread not applicable) 

Ex e II C Gb 

Ex tD A20 IP66


Zone I and Zone 2 

Zone 20, Zone 21 and Zone 22

 

- 40 ℃ ≤ Tservice ≤+100 ℃

- 60 ℃ ≤ Tservice ≤+100 ℃


IP66

f5efee1ec4d66aaa6e7829b57888b30c.png